Recommended home insulation r values.
Roof r value code.
These r values are a sum meaning this should be the total r value once you add up the entire depth of insulation.
Average wall and roof u factor 0 200 in climate zones.
State applicable energy ashrae zone minimum r value state local ms mississippi ashrae 90 1 2010 2 r 20 3 r 20 state local mo.
For example two inches of extruded polystyrene with an r value of 11 has an rsi of 1 93721.
The international codes i codes are the widely accepted comprehensive set of model codes used in the us and abroad to help ensure the engineering of safe sustainable affordable and resilient structures.
The international code council icc is a non profit organization dedicated to developing model codes and standards used in the design build and compliance process.
R value based method of section c402 1 3 u c and f factor based method of section c402 1 4.
Please note that the r values for roof membranes shingles tiles air films and roof deck materials might or might not be permitted by your local code to be included when total roof assembly r value is being calculated for the purpose of satisfying energy code requirements.
Typical recommendations for exterior walls are r 13 to r 23 while r 30 r 38 and r 49 are common for ceilings and attic spaces.
For roofing replacements it is necessary to look at the ibc.
R value is a measure of insulation s ability to resist heat traveling through it.
Always check with your local code authority.
To convert rsi to r value multiply the rsi by 5 67826.
Building and energy codes almost always specify a required minimum r value for exterior walls and roof assemblies with above deck insulation so the minimum required r value in your local jurisdiction is something that you need to take into account when planning a building project.
For example if you have a type of insulation that has an r value of r 5 per inch of thickness you will need a depth of 6 inches of this insulation installed in your attic to reach r 30 if you live in zones 2 or 3.
Code official finds proposed design is satisfactory and complies.
Existing buildings requirements are sprinkled throughout the i codes.
Insulation level are specified by r value.
State applicable code ashrae zone minimum r value state local al alabama 2015 alabama commercial energy code 2 r 25 3 r 25 state local ak alaska 2012 alaska building energy efficiency standard.
Both codes provide specific instructions for re roofing projects and both are clear that replacements must comply with insulation r value requirements if the roof system is part of the building thermal envelope and contains insulation entirely above the deck.
Depending on where you live and the part of your home you re insulating walls crawlspace attic etc you ll need a different r value.